Minimum recommended network speed for upgrade:
- RISE 1 package 50,774 KB * 8 bits / 300 (seconds) = 1.354 Mbps
- RISE 2 FW 92,940 KB * 8 bits / 300 (seconds) = 2.4784 Mbps
Identify if the camera is a RISE 1 / 2 / 3
How to tell the difference between Rise 1, 2 ,3 Series
- Ensure you sync the camera time to the local PC or NTP server.
- From the camera webpage click Date and Time.
- Reboot the camera prior to performing any firmware update.
- Refer to the article on how to obtain firmware files for COHU products Where can I find the latest CostarHD Product software (firmware)?:
- Unzip the file(s).
- From the webpage, go to System > Service > Upgrade Camera.
- Select the file(s) and click upgrade. You may need to browse "all files".
-
RISE 1 you must upload the core package and then the rise package for each revision (3.x, 4.x, 5.x).
The upgrade path is below.- Core Package v3.x.x>Rise Package> 3.x.x
- Core Package v4.1.92 > Rise Package v4.1.323
- Core Package v5.4 > Rise Package v5.4
- Note: v5.2 is the highest update for the 4290 Series
-
RISE 2 there is only 1 package. The upgrade path is below.
- v1.42.5876 > v1.61.7845>1.70.8010
-
RISE 3 there is only 1 package. The upgrade path is below.
-
2.0.2229 > 2.11.2806 > 2.20.3151
-
-
RISE 4 there is only 1 package. The upgrade path is below.
- 4.00.426 > 4.01.576
- If the upgrade fails or hangs, please contact technical support via phone, Zendesk, or email.
-
RISE 1 you must upload the core package and then the rise package for each revision (3.x, 4.x, 5.x).
Comments
0 comments